Rachio 8ZULW Guia de Instalação Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 3
16 ZONE SHOWN
ZONES 1-8
ZONES 9-16
MASTER/
PUMP VALVE
SENSORS
2ND COMMON
WIRE
COMMON
WIRE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Tips for Wiring:
24VAC and ground wires are not needed.
An enclosure is required for hard wiring
installations and/or outdoor installation.
When entering or releasing wires, push down
on terminal block with a small screwdriver.
This will ensure a solid connection.
Solid 18 gauge multi-strand copper wiring is
ideal. If you have thicker gauge wires we
recommend retrotting with 18 gauge wires
using a terminal strip.
Keep all wiring within the recessed triangular
area of the Wall Mount. This ensures the Front
Panel will properly attach.
For wiring diagrams visit www.rachio.com/wiring
or text “wiring” to 1-844-472-2446
?